Seta Labels

Seta dyes are in general more hydrophilic than Square dyes and they are less environment-sensitive. The Seta dyes series spans the whole visible range and the NIR. 

Excitation Light Sources Characteristics Characteristics
Product Number
(Specs Sheet)
Product Name
(Product Info)
Target Group 380 405 436 488 532 594 635 650 680 700 750 780 Medium λ abs
[nm]
ε
[M –1
cm–1]
λ em
[nm]
QY
[%]
FLT
[ns]
Medium λ abs
[nm]
ε
[M–1
cm–1]
λ em
[nm]
QY
[%]
FLT
[ns]
Buy
                               
K8-1342
K8-1342
Seta-670-NHS
Seta-670-NHS
NH2 PB 7.4 667 180,000 688 7 0.42 BSA, D/P=1.5 681 180,000 696 27 2.43
K8-1346
K8-1346
Seta-670-Azide
Seta-670-Azide
triple-CC PB 7.4 667 180,000 686 7 PB 7.4 667 180,000 686 7
K8-1367
K8-1367
Seta-670-pH-di-NHS
Seta-670-pH-di-NHS
NH2 PB 6.0 672 93,000 694 19 IgG, D/P=1 684 703 7
K8-1384
K8-1384
Seta-700-NHS
Seta-700-NHS
NH2 PB 7.4 687 177,000 703 6 IgG D/P=1 705 177,000 715 4
K8-1641
K8-1641
Seta-632-Maleimide
Seta-632-Maleimide
SH PB 7.4 633 270,000 642 5
K8-1642
K8-1642
Seta-632-NHS
Seta-632-NHS
NH2 PB 7.4 632 280,000 641 6 IgG, D/P=1 637 647 18
K8-1663
K8-1663
Seta-633-NHS
Seta-633-NHS
NH2 PB 7.4 633 250,000 644 7 0.25 IgG D/P=1 637 250,000 647 26 1.49
K8-1667
K8-1667
Seta-635-pH-di-NHS
Seta-635-pH-di-NHS
NH2 PB 7.4 640 188,000 656 33 1.8 IgG, D/P=1 646 663 21
K8-1672
K8-1672
Seta-646-NHS
Seta-646-NHS
NH2 PB 7.4 646 207,000 656 10 0.38 IgG, D/P=1 650 207,000 661 33
K8-1682
K8-1682
Seta-660-di-NHS
Seta-660-di-NHS
NH2 PB 7.4 661 220,000 672 11 0.9 IgG D/P=1 665 220,000 675 49
K8-1696
K8-1696
Seta-633-Azide
Seta-633-Azide
triple-CC PB 7.4 633 250,000 644 7 PB 7.4 633 250,000 644 7
K8-3002
K8-3002
Seta-470-NHS
Seta-470-NHS
NH2 water 469 50,000 521 1.9 BSA, D/P=1 469 515 28
K8-3335
K8-3335
Seta-555-NHS
Seta-555-NHS
NH2 PB 7.4 555 155,000 570 7 IgG, D/P=1 556 571 13
K8-3345
K8-3345
Seta-555-DBCO
Seta-555-DBCO
N3 PB 7.4 555 155,000 570 7
K8-3346
K8-3346
Seta-555-Azide
Seta-555-Azide
triple-CC PB 7.4 555 155,000 570 7
K8-5035
K8-5035
Seta-650-NHS
Seta-650-NHS
NH2 PB 7.4 651 200,000 671 28 IgG, D/P=1 654 673 37
K8-5036
K8-5036
Seta-650-Maleimide
Seta-650-Maleimide
SH PB 7.4 652 200,000 672 28
K8-5045
K8-5045
Seta-650-DBCO
Seta-650-DBCO
N3 PB 7.4 653 200,000 674 28
K8-5046
K8-5046
Seta-650-Azide
Seta-650-Azide
triple-CC PB 7.4 651 200,000 671 28
K8-5075
K8-5075
Seta-680-NHS
Seta-680-NHS
NH2 PB 7.4 678 200,000 698 24 IgG, D/P=1 680 701 30
K8-7045
K8-7045
Seta-750-DBCO
Seta-750-DBCO
N3 PB 7.4 754 234,000 782 21
K8-7046
K8-7046
Seta-750-Azide
Seta-750-Azide
triple-CC PB 7.4 750 200,000 779 22
K8-7055
K8-7055
Seta-780-NHS
Seta-780-NHS
NH2 PB 7.4 777 215,000 807 1.2
K8-1388
K8-1388
Seta-700-di-NHS
Seta-700-di-NHS
NH2 PB 7.4 688 180,000 704 11 IgG D/P=1 696 713 23
K8-1341
K8-1341
Seta-670-Maleimide
Seta-670-Maleimide
SH PB 7.4 667 180,000 688 7
K8-1671
K8-1671
Seta-646-Maleimide
Seta-646-Maleimide
SH PB 7.4 647 210,000 657 8 IgG, D/P=1 650 661 31
K4-205
K4-205
Seta-375-NHS
Seta-375-NHS
NH2 PB 7.4 372 24,500 476 86 3.1 IgG, D/P=5 372 24,500 480 42 3.5
K8-7522
K8-7522
Seta-750-NHS
Seta-750-NHS
NH2 PB 7.4 753 230,000 780 14 IgG D/P=1 756 783 17
K8-3003
K8-3003
Seta-470-Maleimide
Seta-470-Maleimide
SH Water 469 50,000 521 1.9 EtOH 462 50,000 515 2.2
K4-225
K4-225
Seta-385-NHS
Seta-385-NHS
NH2 PB 7.4 384 25,000 512 78 IgG, D/P=6 387 25,000 505 29
K8-1389
K8-1389
Seta-700-NHS
Seta-700-NHS
NH2 PB 7.4 688 162,000 703 14 IgG D/P=1 694 710 18
K6-5052
K6-5052
Seta-405 NHS
Seta-405 NHS
NH2 PB 7.4 401 30,000 452 70 IgG D/P=1 405 453 56
K4-215
K4-215
Seta-400-NHS
Seta-400-NHS
NH2 PB 7.4 399 24,000 576 34 IgG D/P=1 401 569 19
K8-1662
K8-1662
Seta-640-di-NHS
Seta-640-di-NHS
NH2 PB 7.4 636 181,000 646 13 0.7 IgG D/P=1 640 650 30

Seta-375-NHS is an extremely bright, reactive label for use with the UV 375 - 380 nm diode lasers. It is a much brighter alternative for Alexa 350 with a much higher extiction coefficient and quantum efficiency. Exc./Em. max: 372/480 nm.

Seta-470-NHS is a fluorescent label perfectly suited for the 447, 457 and 473 nm diode lasers. It is a fluorescent viscosity probe for biomedical imaging and sensing applications and combines good solubility in water and aqueous buffers, high photostability, a large Stokes' shift and absorption and emission wavelengths in the visible range. Its extinction coefficient is 50,000 M–1cm–1 and it exhibits highly increased QYs after covalent attachment to proteins. Exc./Em. max: 469/515 nm.

Seta-555-NHS is a direct replacement for Cy3, Alexa 555 or DyLight 550 and can therefore be used with these filter sets. Its extinction coefficient is 154,000 M–1cm–1 and the QY of Seta-555-NHS is about twice as high as that of Cy3.

Seta-632-NHS is a better alternative to Alexa 633: it has an extinction coefficient of 280,000 M–1cm–1 as compared to 159,000 M–1cm–1 for Alexa 633. It is also an extremely good acceptor dye for use in FRET applications with lanthanide (Sm(III)-)donors [30]. Emitting bright red fluorescence, this dye can be used with the Alexa 633 filter set. Exc./Em. max of IgG-conjugates: 637/647 nm.

Seta-633-NHS is a hydrophilic, mono-reactive label for proteins and other biomolecules. It is extremely bright and has a low tendency for self-quenching even at higher D/P ratios. The extinction coefficient is 250,000 M–1cm–1as compared to 159,000 M–1cm–1 for Alexa 633 or 170,000 M–1cm–1 for DyLight 633, and quantum yields as high as 70% were measured with conjugates of this long-wavelength dye. It is optimally suited to be excited with the 633 nm spectral line of the He-Ne laser or the 635 nm line of red diode lasers and replaces Alexa 633 and/or DyLight 633. Exc./Em. max of IgG-conjugates: 637/647 nm. It is well-suited as a label in fluorescence lifetime-based assays as shown below in the example of biotin.

Changes in phase angle upon titration of Seta-633-biotin
with anti-biotin. Y. Povrozin et al. Bioconjugate Chem.,
2009, 20, 1807–1812
.

Seta-646-NHS is extremely bright (extinction coefficient is 210,000 M–1cm–1, and the quantum yield of labeled antibodies are as high as 33% at a D/P ~ 1) and an ideal replacement of Cy5, Alexa 647, or DyLight 650 producing intense red fluorescence emission. It is also extremely photostable and can be optimally excited with the 647 nm spectral line of the Krypton-Argon laser. Exc./Em. max for conjugates: 650/661 nm.

Our proprietary Seta-650-NHS is a brighter (extinction coefficient is ~200,000 M–1cm–1, and the quantum yield of labeled antibodies are as high as 33% at a D/P ~ 1) replacement for Cy5 or DyLight 650 producing intense red fluorescence emission. It is a highly photostable dye that is optimally excited with the 647 nm spectral line of the Krypton-Argon laser. Exc./Em. max for conjugates: 650/671 nm. Not licensed for use in TR-FRET.

Seta-650 (K8-5035) and Seta-750 (K8-7522)-conjugated PEG-single walled carbon nanotubes (PEG-SWCNT-650 or PEG-SWCNT-750) were produced by labeling the PEG terminal amino groups on amino-modified PEG-SWCNTs with either Seta-650-NHS or Seta-750-NHS.
Cartilage ECM trafficking and chondrocyte internalization of injected PEG-SWCNTs: Polyethylene-Glycol-Modified Single-Walled Carbon Nanotubes for Intra-Articular Delivery to Chondrocytes, M. Bottini et al. ACS Nano, 2014, 8 (12), 12280–12291.

Seta-660-di-NHS is much brighter alternative to Alexa 660: Its extinction coefficient is 220,000 M–1cm–1 as compared to 132,000 M–1cm–1 for Alexa 660, and quantum yields as high as 50% were measured from IgG-conjugates with this long-wavelength marker. It emits intense fluorescence in the far-red region of the light spectrum. Ex./Em. max: 661/672 nm.

Seta-680-NHS is a dye that replaces Cy5.5, Alexa 680 or DyLight 680. The dye has an extinction coefficient of 200,000 M–1cm–1 as compared to 160,000 M–1cm–1 for DyLight 680 and its IgG-conjugates are bright and photostable. Ex./Em. max: 678/698 nm.

Seta-700-NHS is a bright, water-soluble fluorescent label with a Q.Y. of up to 20% when labeled to IgG. Replaces Alexa 700 (QY = 0.13). Ex./Em. max (IgG-Conjugate): 694/710 nm.

Seta-750-NHS is a hydrophilic, mono-reactive label with almost identical absorption and emission as Cy7 or Alexa 750 and can therefore be used with these filter sets. It combines high photostability and brightness. Replacement for Cy7, Alexa 750 and DyLight 750. Its extinction coefficient is 230,000 M–1cm–1. Ex./Em. max: 753/780 nm.

In-vivo analysis of the biodistribution of fluorescently labelled PEG-single wall carbon nanotubes: Panels show recording of fluorescence in mice injected with PBS (a) Seta750 (b) and PEG-SWCNT-750 (c). No fluorescence was recorded in control mice (a) at any time. Already 10 min after the injection, animals that received the fluorophore Seta750 alone (b) displayed fluorescence almost exclusively localized in the bladder. High fluorescence was recorded in liver and brown fat of mice administered with PEG-SWCNT-750 (c); one hour after the injection bladder accumulation of fluorescence was also visible in this group. From: M. Bottini et al. Biodistribution and toxicity of pegylated single wall carbon nanotubes in pregnant mice. Particle and Fibre Toxicology 2013 10:21.

C. Sacchetti et al. Surface Polyethylene Glycol Conformation Influences the Protein Corona of Polyethylene Glycol-Modified Single-Walled Carbon Nanotubes: Potential Implications on Biological Performance. ACS Nano. 2013 Mar 26;7(3):1974-89.

 All dyes are available in the following formats: carboxyl, NHS-esters and maleimides.

 

Please provide following information to download software:

Your Name*:
Email ID*:
Contact Number:
Cancel